4-zone modulating controller
Part number: AS-ZC-4M
A wall controller for four zones. Each zone can be set to 25, 50, 75 or 100% open, not just on or off, with four LEDs showing the position. Any zone can be set as the spill zone.
| Zones | 4 |
|---|---|
| Positions | 25, 50, 75, 100% or closed |
| Supply | 24 VAC ±10%, 50 Hz |
| Zone output | 200 mA per channel |
Overview
Most zone controllers only open or close a zone. This controller sets each zone to 25, 50, 75 or 100% open. Press OPEN once for fully open, and press again to step through the settings. Four LEDs on each zone show where the damper sits.
Any one zone can be set as the spill zone. When every other zone is closed, the spill zone opens on its own to relieve duct pressure. This protects the fan and stops the ducts from over-pressurising. Choose a duct near a return air grille, a corridor or a plant room, not a bedroom or office.
Damper positions and the spill setting are kept if the power goes out. The controller runs on 24 VAC from our 240 V to 24 V transformer and drives one F03 actuator per zone.
Typical applications
- Homes and apartments
- Small offices and shops
- Upgrading an open/close system
- Jobs where zones need part-open settings
Part numbers
Choose a quantity and add each part to your quote list. Prices are sent by written quote.
| Part number | Description | Size (mm) | Material | Unit | Quote |
|---|---|---|---|---|---|
| AS-ZC-4M | 4-zone modulating controller | 4 zones | Each |
Specifications
Control
| Zones | 4, each controlled on its own |
|---|---|
| Positions per zone | 25%, 50%, 75% and 100% open, or closed |
| Position display | Four LEDs per zone |
| Spill zone | Any one zone, set at the controller |
| Power loss | Positions and spill setting kept after power returns |
| Zone labels | Pre-printed and blank labels included |
Electrical
| Supply | 24 VAC ±10%, 50 Hz |
|---|---|
| Built-in fuse | 2.0 A resettable |
| Zone output | 24 VAC, 200 mA per channel |
| Cable to actuator | 20 m maximum |
Environment
| Operating temperature | −10 °C to +60 °C |
|---|---|
| Operating humidity | 10 to 80% RH, non-condensing |
| Altitude | 0 to 2000 m |
Specifications may change without notice. Contact us to confirm details for your project.
Wiring
Connect the transformer to 240 VAC mains (licensed electrician) and its 24 VAC output to the controller. Connect each F03 actuator to a channel, CH1 to CH4.
Compatible products
Products that are often specified with the 4-zone modulating controller.
- F03 motor kit
Everything needed to motorise a zone, in one part number.
AS-MK-F03
F03 damper actuator24 VAC damper actuator that holds any position. 3.9 N·m running torque, 1 RPM.
AS-ACT-F03-24- 240 V to 24 V transformer
Steps 240 VAC mains down to 24 VAC for the controller and actuators.
AS-TRF-24
Six-core motor cable, 15 mOne 15 m plug-in lead carries power and signal from controller to actuator.
AS-CBL-6C-15M
Frequently asked questions
How do I set the spill zone?
Press and hold the OPEN button of the zone for more than 5 seconds. All four LEDs on that zone flash to confirm. To cancel, hold the CLOSE button of the spill zone for more than 5 seconds.
Which zone should be the spill zone?
Use a duct near a return air grille, a corridor or a plant room. Do not use a bedroom or office, because the spill zone will open on its own and affect comfort in that room.
What happens after a power cut?
Damper positions and the spill setting are kept. The zones return to where they were once power comes back.